Product Details:
|
Power Source: | 380V, 50/60 Hz | Type: | Fire Testing Equipment |
---|---|---|---|
Dimensions: | 7, 000(W)*4, 000(D)*4, 000(H)M | Weight: | 850kg |
Burner: | Length 100mm, Inner Diameter 9.5mm | Burning Angle: | 90º |
Flame Height: | 20mm | Warranty: | 12 Months |
Highlight: | horizontal flammability tester,vertical flame test chamber |
Laboratory fume hood: |
inside volume 0.5m3 |
chamber permits observation of tests |
normal thermal circulation of air during burning |
inside surface should be dark color |
light level shall be less than 20lx |
exhaust fan to remove combustion |
exhaust fan should be turned off during testing |
Optional: mirror to capture rear view |
Laboratory burner: |
tube with length 100±10mm |
inside diameter 9.5±0.3mm |
compliance with ASTM D 5025 |
IEC TS60695-11-4 Method A (tech equ ASTM D 5025) |
and ignition source P/PF2 os ISO 10093 (tech equ ASTM D 5025) |
Burner Wing Tip (used in HBF, HF-1 HF-2) |
length of slit 48±1mm |
width 1.3±0.05mm |
Burner Mounting Fixture: |
20 degree from vertical axis (used in 5VA,5VB) |
Ring stands |
for horizontal and vertical postioning of specimen or wire gauge |
stands with clam adjustable to desired angles and heights constructed from aluminium or steel |
Timing devices- accurate to 0.1sec |
measuring scale- graduated in mm |
gas supply- technical grade methane gas (min 98% pure) with regulator and meter for uniform gas flow |
Wire gauze: |
approximatel 20 opening per 25mm |
made with 0.43±0.03mm diameter iron or steel wire and cut to approx 125mm squares (used in HB) |
conditioning room or chamber : 23± 2 deg C temp |
Humdity 50±10 % |
HB support Fixture-(used in HB) |
metal support fixture for specimen that are not supporting |
Micrometer- capable of being read to 0.01mm |
cotton- a supply if absorbent 100% cotton |
dessicator- containing anhydrous calcium chloride |
maintaining at relative humidity exceeding 20% at 23±2deg C |
conditioning oven- min of 5 air changes per hour, maintained at 70±2deg C |
specimen mandrel form- 12.7±0.5mm diameter rod with min 250mm length (used in VTM-0, VTM-1, VTM-2) |
Tape-pressure sensitive adhesive (used in VTM-0, VTM-1, VTM-2) |
Support gauze (used in HBF, HF-1, HF-2) |
wire cloth plain weave, low caron, plain steel or stainless steel |
approx 215mm longX75mm wide having 13mm length bent to form a right angle at one end |
consist of 6.4mm mesh gauze constructed of 0.88±0.05mm dia steel wire |
cloth mesh and wire dia to be determined as per ASTM E 437 |
Foam support fixture(used in HBF, HF-1, HF-2) |
fixture capable of holding support gauze including height adjustment |
Manometer/ pressure gage- capable of measuring 200mm of water with increment of 5mm |
Flow meter- a rotameter calibrated as per practice of rotameter calibration D 3195, with correlation curve appropriate to gas, or a mass flow meter with ± 2 percent accuracy. |
Model | DX8379-UL94 |
Dimensions | About 7, 000 (w) X4, 000 (D) X4, 000 (H)m |
Power supply | AC 380V, 50/60Hz |
Brochure | Can provide |
Air Velocity | 19±8 Km/h |
---|---|
Tools | Propane gas/liquefied natural gas, Compressed air, Vacuum cleaners, Computer |