Product Details:
|
Standard: | IEC61730 | Inside Size: | 700 X 400 X 810mm |
---|---|---|---|
Open Area: | 25x25mm, Height: 50mm | Burner: | 45° Angle, Flame Height: 20mm |
Timer: | 0-99.99s/MH Can Be Set | Supply Power: | 220V |
Highlight: | IEC 61730 Fire Testing Equipment,Module Cell Fire Testing machine |
Serial number
|
Parts
|
Parameters
|
1
|
Intake fan and intake guide device
|
Introduce outdoor air, adjustable fins to avoid air turbulence.
The inlet fan can be controlled remotely.
|
2
|
Anemometer
|
At least 3 anemometers, the wind speed reaches 5.3 ± 0.2 m/s;
The accuracy of the anemometer is 0.2m/s;
|
3
|
Air flue
|
Air duct material, stainless steel.
The height of the air duct from the ground: 1111 ± 100 mm;
The internal dimensions of the air duct: 2133.6 ± 100 mm * 762mm;
The length of the air duct: the temperature at three points reaches 5.3 ± 0.2 m/s.
|
4
|
Burner
|
Burner size: refer to UL790;
Burner length: 1,120mm ± 0.1 mm;
Burner inner diameter and outer diameter: inner diameter is 50.9 mm ± 0.1 mm, outer diameter is 60.3 ± 0.1 mm;
Nozzle size: (12.7 ± 0.1) mm X (910.0 ± 1.5) mm (width X length);
Ports on both sides: inner diameter (25 ± 0.13 mm) and outer diameter 33.4 ± 0.13 mm);
With automatic ignition function and equipped with ignition gun;
|
5
|
Temperature thermocouple
|
Type: Type K
There should be a fixture so that the thermocouple can test the flame
temperature.
At least reach the test range above 800°
Response time: <1S
|
6
|
Test holder
|
The test frame can fix the sample, and the test frame needs to be made of refractory material.
The angle of the test frame can be adjusted within a range of 30° from the horizontal. The angle of the test frame can be adjusted by gears. The test stand is equipped with an angle indicator, the angle accuracy of the indicator is 0.01°. The place of 22.62° shall be marked. The angle indicator has a temperature resistance of at least 800℃ and is a non-flammable material.
The size of the test stand must reach 1.5m*2.3m, and thin-film modules and crystalline silicon modules must be installed.
The test rack needs to be equipped with a loading table and an operating table.
The test stand should be equipped with stainless steel trays to collect waste after the test.
The test rack should be equipped with a bracket for installing the components, and the bracket is detachable.
|
7
|
Anti-backboard
|
Install between the test frame and the air duct, and place the flame recoil.
|
8
|
Air duct thermocouple
|
Monitor the air temperature in the air duct
|
Contact Person: Sophia Su
Tel: +86-13266221899