Product Details:
|
Product Name: | EN149 Respirator Breathing Resistance Tester | Standard: | EN149, EN143 |
---|---|---|---|
Size: | (W×D×H) (600*600*750)mm | Weight: | 35kg |
The Power Consumption: | 1.3w | Warranty: | 12 Months |
Highlight: | EN149 2000 Respirator Breathing Resistance Tester |
EN149 Respirator Breathing Resistance Tester
Main parameters of respirator air resistance tester and respirator respiratory resistance tester:
The test flow | (85±1)L/min 0.1L/min was better than ±2.5% |
Tooling head | large, medium and small (new standard) |
Pressure range | ±1500Pa 0.1Pa is better than 1% |
Data stores | 500 groups |
Overall size | (W×D×H) (600*600*750)mm |
The weight of the machine | 35kg |
The power consumption | 1.3w |
Equipment standard:
EN 13274-3,GB 2626-2019, GB/T 32610-2016, EN149, EN143
Principle of protective mask breathing resistance tester:
1. The instrument consists of a breathing air source that can adjust the flow rate, a human head mold specified by the standard, an inhalation and exhalation pipeline system, and a respiratory resistance measurement system.
2. The use of special air path conversion elements ensures that the exhalation and inhalation systems can be replaced easily and quickly.
3. Digital display of respiratory resistance, with zero point correction, accuracy correction and over-range alarm function.
4, using standard flowmeter, high flow control accuracy.
5. Computer control and acquisition system Realize the control of pressure, the control of breathing frequency and the real-time detection and output of test data of respiratory resistance.
Operation steps:
1. Turn on the air source
2. Air flow 95L / min
3. Pressure 0.3pa
4. Installation sample
5. Test time: 60s
6. Replace the sample
Contact Person: Sophia Su
Tel: +86-13266221899