• English
Home ProductsMask Tester

Mask Flame Resistance Testing Equipment For Testing Flame Retardant Performance Of Mask

Certification
China DONGGUAN DAXIAN INSTRUMENT EQUIPMENT CO.,LTD certification
China DONGGUAN DAXIAN INSTRUMENT EQUIPMENT CO.,LTD certification
Customer Reviews
Before I buy the machine, I see our partner use your machine, after receive it, all is good. thanks, hope make deal next time too.

—— Max Will

At the beginning I worry about if your company can delivery in time, It turns out your company is good, no delay,A pleasant collaboration.

—— Peter Huang

Nice cooperation! We appreciated for your company's kind support on our projects. Very good service.

—— Mr Hussain

Professional quotation, professional technology, so that we receive timely goods, trustworthy enterprises.Hope we can still cooperate next time!

—— Mr. Paul Garry

I'm Online Chat Now

Mask Flame Resistance Testing Equipment For Testing Flame Retardant Performance Of Mask

Mask Flame Resistance Testing Equipment For Testing Flame Retardant Performance Of Mask
Mask Flame Resistance Testing Equipment For Testing Flame Retardant Performance Of Mask
Mask Flame Resistance Testing Equipment For Testing Flame Retardant Performance Of Mask Mask Flame Resistance Testing Equipment For Testing Flame Retardant Performance Of Mask

Large Image :  Mask Flame Resistance Testing Equipment For Testing Flame Retardant Performance Of Mask

Product Details:
Place of Origin: China
Brand Name: Daxian
Certification: GB/T16556
Model Number: DX8220
Payment & Shipping Terms:
Minimum Order Quantity: One set
Price: Negotiation
Packaging Details: Wooden Case
Delivery Time: 15 work days
Payment Terms: L/C,D/A,D/P,T/T,Western Union,MoneyGram,In cash
Supply Ability: 15 sets per month

Mask Flame Resistance Testing Equipment For Testing Flame Retardant Performance Of Mask

Description
Standard: GB/T16556 Scope Of Application: Of The Mask
Function: Suitable For Testing The Flame Retardant Performance Test Sample: Mask
Gas Source: Propane Relative Humidity: ≤85%
Ambient Temperature: -5°C-30°C Power Supply Voltage: 220V±10%, 50HZ, 100W
Highlight:

Mask Flame Resistance Testing Equipment

DX8220 Mask Flame Resistance Testing Equipment

Mask Flame Resistance Testing Equipment For Testing Flame Retardant Performance Of Mask 0

Scope of application: It is suitable for testing the flame retardant performance of the mask, the instrument has six burners to apply flame to the test sample, and the test time is displayed digitally.

Conform to the standard: developed in strict accordance with the main technical parameters of the national standard GB/T16556.

Features: Automatic timing, digital display

The working conditions and main technical indicators of the instrument

a. Ambient temperature: -5°C-30°C;

b. Relative humidity: ≤85%;

c. Power supply voltage: 220V±10%, 50HZ, 100W;

d. The temperature of the burner flame at 250mm reaches 950 °C± 50 °C;

e. The flame application time is steplessly adjustable

f. Gas source: propane;

7. Test sample: mask.

Test steps:

a. Turn on the power supply and air source of the instrument, and check whether the "pressure adjustment", "flow adjustment" and "permanent lamp adjustment" on the instrument panel are in the off position.

b. Open the door of the test chamber, move the headform to install the test sample on the headform, adjust the distance from each burner to the test sample to 250mm according to the national standard, and manually remove the sample from the burner.

c. Turn on the power switch and the main valve of the gas source on the instrument, adjust the knob of "Everbright Light Adjustment" on the panel, and light the everlasting lamp with an open flame, the flame is about 20mm long. Press the "?" on the instrument panel display. button and then press the "▲" button, the monitor displays "1005".

The "pressure adjustment" on the adjustment instrument makes the indicated value of the pressure gauge around 0.12Mpa.

d. Press the "Run" button to adjust the "flow adjustment", at this time the burner is lit, adjust the air feed nut at the lower end of the burner, measure the temperature at the flame 250mm with a temperature measuring instrument to (950±50) °C, press the "Reset" button to extinguish the burner flame.

e. Then adjust the monitor on the panel and press "?" button, then press the "▲" button to display "0005", manually move the test sample to the test position, press the "run" button burner to ignite, the display starts to time, the burner will automatically extinguish after 5 seconds of flames, and the re-ignition time will start to time, pay attention to observe whether there is any re-combustion after the sample is flamed, if the re-combustion stops, press the "timing" button on the instrument, and the display will stop timing.

f. Record the continuous combustion time and observed phenomena.

g. Replace the sample with a new one and repeat operations 3.2-3.6. After the test, turn off the power supply and gas source, and clean and maintain the combustion box.

Packing list:

a. 1 test chamber and 1 headform

b. 1 medium pressure valve

c. Power cords: 1 pcs

d. fuses 0.5A: 2pcs

e. rubber tubes, 1.5 m

f. 1 copy of the instruction manual

g. 1 certificate of conformity

Contact Details
DONGGUAN DAXIAN INSTRUMENT EQUIPMENT CO.,LTD

Contact Person: Miss. Sophia Su

Tel: +86-13266221899

Send your inquiry directly to us (0 / 3000)