• English
Home ProductsRubber Testing Equipment

IEC62730-2024 5000hrs Insulators Dry Heat and Humidity Multiple Stress Tester

Certification
China DONGGUAN DAXIAN INSTRUMENT EQUIPMENT CO.,LTD certification
China DONGGUAN DAXIAN INSTRUMENT EQUIPMENT CO.,LTD certification
Customer Reviews
Before I buy the machine, I see our partner use your machine, after receive it, all is good. thanks, hope make deal next time too.

—— Max Will

At the beginning I worry about if your company can delivery in time, It turns out your company is good, no delay,A pleasant collaboration.

—— Peter Huang

Nice cooperation! We appreciated for your company's kind support on our projects. Very good service.

—— Mr Hussain

Professional quotation, professional technology, so that we receive timely goods, trustworthy enterprises.Hope we can still cooperate next time!

—— Mr. Paul Garry

I'm Online Chat Now

IEC62730-2024 5000hrs Insulators Dry Heat and Humidity Multiple Stress Tester

IEC62730-2024 5000hrs Insulators Dry Heat and Humidity Multiple Stress Tester
IEC62730-2024 5000hrs Insulators Dry Heat and Humidity Multiple Stress Tester
IEC62730-2024 5000hrs Insulators Dry Heat and Humidity Multiple Stress Tester IEC62730-2024 5000hrs Insulators Dry Heat and Humidity Multiple Stress Tester IEC62730-2024 5000hrs Insulators Dry Heat and Humidity Multiple Stress Tester IEC62730-2024 5000hrs Insulators Dry Heat and Humidity Multiple Stress Tester IEC62730-2024 5000hrs Insulators Dry Heat and Humidity Multiple Stress Tester IEC62730-2024 5000hrs Insulators Dry Heat and Humidity Multiple Stress Tester

Large Image :  IEC62730-2024 5000hrs Insulators Dry Heat and Humidity Multiple Stress Tester

Product Details:
Place of Origin: China
Brand Name: DAXIAN
Certification: IEC62730-2024、IECIEC62217-2012
Model Number: DX8428
Payment & Shipping Terms:
Minimum Order Quantity: 1 set
Price: negotiation
Packaging Details: wooden case
Delivery Time: 8-10 work days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 3 sets per month

IEC62730-2024 5000hrs Insulators Dry Heat and Humidity Multiple Stress Tester

Description
Machine Name: Insulators 5000hrs Multiple Stress Test Machine Standard: IEC62730-2024、IECIEC62217-2012
Test Sample: Insulators Material: Printed
Weight: 1ton Dimentions: 3.1* 3.2* 3.6m
Delivery Time: 15 Work Days Warranty: 12 Months
Highlight:

5000hrs Insulators Dry Heat Tester

,

IEC62730-2024 Insulators Dry Heat Tester

,

Multiple Stress Insulators Dry Heat Tester

IEC62730-2024,IEC62217-2012 Polymeric Insulators 5000hrs Multiple Stress Test Machine

 

IEC62730-2024 5000hrs Insulators Dry Heat and Humidity Multiple Stress Tester 0

IEC62730-2024 5000hrs Insulators Dry Heat and Humidity Multiple Stress Tester 1

 

 

1. Test sample: Two test insulators of the same design with a creepage distance between 500mm and 800mm,

2. Procedure: Conduct the test in a sealed, damp, and corrosion-resistant test chamber, with a volume not exceeding 20M3. Figure B1 is a schematic diagram of this test chamber

3. Separate observation holes for wipers and movable ultraviolet filters to observe the equipment in the experiment.

4. Test conditions: As shown in Figure B2, various stress cycles are applied to the insulator, which are repeated for about 5000 hours. During the equipment cycle test, the test sample should be subjected to temperature changes and condensation.

5. As shown in Figure B3, the test is installed vertically in the middle of the test, with a minimum distance of 400mm between the adjacent umbrella edges of the test specimen and the top, as well as between the test specimen and the wall and ground Before the experiment begins, the test sample should be cleaned with deionized water,

7. Up to three pairs of samples with similar creepage distances can be tested simultaneously

8. Voltage: The value obtained by dividing the creepage distance of the test sample (in mm) by 34.6 (equivalent to a creepage distance of 20mm/KV, calculated based on the phase to phase voltage)

9. For the power circuit, when the continuous negative current load is 250mA (r.m.s), the maximum voltage drop on the high voltage side during 1 second should not exceed 5%, and the protection level should be adjusted to 1A (r.m.s)

10. Sunlight simulation: The simulated solar radiation is provided by a xenon arc lamp with a nominal output of 6500W and equipped with two borosilicate glass filters (see example B.4), with a distance of approximately 480mm between the xenon arc lamp and the test sample

11. At the beginning of each experiment, a new lamp and filter should be used. During the experiment, when replacing the filter (and if the lamp is also necessary), it should be done according to the recommendation of the lamp manufacturer.

DX8428 Insulator Multi Stress Testing Machine.pdf

 

 

IEC62730-2024 5000hrs Insulators Dry Heat and Humidity Multiple Stress Tester 2


 

Welcome to visit our factory for sightseeing!

 

Supplier Company Name Daxian Instrument Equipment CO.,Limited
Company Address Changlian Industrial Building, 168 Zhenan West Road, Xiabian Community, Chang'an Town, Dongguan, Guang Dong, China
Contact Person Sophia Su
Mobile Number 86-13266221899
Telephone Number 86-0769-82759287

Contact Details
DONGGUAN DAXIAN INSTRUMENT EQUIPMENT CO.,LTD

Contact Person: Sophia Su

Tel: +86-13266221899

Send your inquiry directly to us (0 / 3000)