Product Details:
|
Power: | AC 220V/50HZ | Usage: | Flammability Tester |
---|---|---|---|
Standards: | IEC60587-2007, ASTM D2303 | Drop Height: | 30mm ~ 40mm Adjustable |
Test Voltage: | 100~6000V Adjustable | Warranty: | 12 Months |
Highlight: | 6KV High Voltage Tracking Index Tester,ASTM D2303 Flammability Tester,IEC60587 Flammability Tester |
IEC60587 6 KV Automatic High Voltage Tracking Index Tester
Technical Description:
This product is used in electrical products under the influence of moisture and impurity environment, between the different polarity of the live parts or between the live parts and the grounding metal parts may cause insulation on the leakage, the resulting arc caused by electrical breakdown of the electrical or due to Discharge causes the material to erode and even ignite the fire. The test apparatus is a destructive test of the insulating material in the above case to test and evaluate the relative resistance to traceability of the insulator in the presence of electric and impurity water at a specified voltage. Applicable to electrical and electronic products, household appliances, solid electrical insulation materials and their products, such as: relay socket, switch cover, contactor body.
Standard:
IEC60587-2007, ASTM D2303
Parameters:
Name | High Voltage Tracking Index Tester |
Box |
≥ 0.5 cubic meters |
Drop size |
44 to 50 drops / cm3 |
Power supply |
AC 220V, 50Hz |
Electrical load |
100 ~ 6000V adjustable |
Drip height |
30mm ~ 40mm adjustable |
Electrode Pressure |
1.00N±0.05N |
Flow range | 0.00185 to 2 ml / min |
Working speed | 0.1 to 15 rev / min |
1. DC voltage: display the voltage of DC test, which can be realized by adjusting voltage regulator.
2. AC voltage: display the voltage of AC test, which can be realized by adjusting voltage regulator.
3. DC current (1 ~ 5): there are five groups of DC current display, display the current value of five groups of DC test, the set value is 60mA.
4. AC current (1 ~ 5): there are five groups of AC current display, display the current value of five groups of AC test, the set value is 60mA.
5. Reset: 1. When the tester alarms, press this button to stop the alarm; 2. Press this button to stop the test, and all the current values in the main test screen are cleared
6. Power supply: it can control the on-off of power supply and has the function of leakage protection.
7. Resistance gear: select the gear of series resistance value.
Our Advantage:
1. ISO9001:2008 certification
2. Professional and rich experienced staff
3. Both standard and Non-standard service are provides
4. 95% products export to foreigner countries
5 .Best service after shipment with emails.
Contact Person: Sophia Su
Tel: +86-13266221899