Standard:GB12666.6,IEC60331
Scope of application:Suitable for testing the fire resistance characteristics of mineral insulated cables and wires and cables with fire-resistant layers
Size:(W)1500×(D)550×(H)1400mm
Minimum Order Quantity:1
Price:Negotiation
Packaging Details:Wooden case
Minimum Order Quantity:1
Price:Negotiation
Packaging Details:Wooden case
Standard:GB/T5169.10, GB/T5169.13-2006, IEC60695-2-10:2000, GB2099, VDE 0620, GB4706.1, UL817 standards
Scope of application:used to test the stability of electronic and electrical products during operation
Test chamber volume:0.5M³, depth x width x height: 60x 95x 90cm
Standard:GB12666.6,IEC60331
Scope of application:Suitable for testing the fire resistance characteristics of mineral insulated cables and wires and cables with fire-resistant layers
Size:(W)1500×(D)550×(H)1400mm
Standard:GB/T 3048.1-2007,GB/T 3048.7-2007
Scope of application:used for the ability of wires and cables to withstand damage caused by electric traces caused by surface leakage under dirty conditions
Test voltage:0~6000v adjustable
Standard:ASTM D2275-14
Scope of application:Suitable for scientific research institutions, the developed solid insulation material corona aging resistance testing system can achieve different corona test conditions
Electrode spacing:100mm
Scope of application:Mainly used to determine the concentration of smoke released by cables and optical cables during combustion
Standard:GB/T17651.1~2-1998、IEC61034-1~2
Temperature:5℃~30℃
Scope of application:It is suitable for assessing and measuring the performance of circular cables or circular insulated cores at low temperatures
Standard:GB2951.4, GB2099-94, VDE0472 and IEC884-1
Diameter of low-temperature winding specimen:Ф2.5~Ф12.5mm
Standard:GB/T5023.2-2008/IEC60227-2:2003,GB/T5013.2-2008/ IEC60245-2:1998
Scope of application:It is mainly suitable for testing the flexure test of rubber and plastic insulation and sheathed flexible cable
Test current:0.1A
Standard:UL1581 sect 1080.1~1080.14, VW-1(V-ertical-specimen)Flame Test
Test method:Adjust the flame height, place the top of the flame under the specimen, burn for 15 seconds, extinguish for 15 seconds, repeat 5 times, and check the burning condition of the specimen.
Combustion chamber effective space:2.4m (length) * 1m (width) * 1.8m (height)
Scope of application:Suitable for conducting vertical slow flame propagation tests on a single wire, cable or optical cable under specified flame conditions, and can also verify the combustion of droplets under flame conditions
Standard:GB/T18380.11-2008、GB/T18380.12-2008、GB/T18380.13-2008、IEC60332-1-1:2004
Igniter:for automatic high-pressure ignition